What the rules say
The Control of Pollution (Oil Storage) (England) Regulations 2001 require oil stored at business premises in containers over 200 litres to have secondary containment that holds 110% of the tank, with the fill pipe, vent and gauge inside the bund. Domestic tanks under 3,500 litres are exempt, but a holiday let run as a business is treated as business premises by OFTEC and the Environment Agency, so plan on a bunded tank. Tanks near a watercourse, borehole or drain must be bunded whatever the size.
Leaks are the real risk. Single-skin plastic tanks over about 10 years old split along the seams, and a slow leak into the ground under a cottage can mean excavating the floor. OFTEC's inspection checklist covers the tank, its base, the supply pipe and the fire separation distances from the building and boundaries.
What to do
- Find out what you have: single-skin or bunded, size, age and base.
- Have the tank inspected with the annual boiler service and act on the report.
- Fit a tank alarm or gauge you can read remotely, and keep the fill point locked.
- Keep a note of the fuel supplier and a spill kit near the tank.
Elsewhere in the UK
Scotland: The Water Environment (Oil Storage) (Scotland) Regulations 2006 apply to all oil storage over 200 litres, including domestic, so bunding is required.
Wales: The Control of Pollution (Oil Storage) (Wales) Regulations 2016 apply to all oil storage over 200 litres, domestic included.
Northern Ireland: The Control of Pollution (Oil Storage) Regulations (Northern Ireland) 2010 apply to non-domestic storage over 200 litres and domestic storage over 3,500 litres.
Tips from the field
- Oil theft from holiday lets is common in winter. A locked fill cap and a tank in view of the house help, and insurers often ask what security you have.
Common questions
Does a holiday let oil tank need to be bunded?
Almost always. The English regulations exempt domestic tanks under 3,500 litres, but a holiday let run as a business is treated as business premises, and in Scotland and Wales all tanks over 200 litres must be bunded.
How often should an oil tank be inspected?
A visual check at each changeover for drips, bulging or cracks, and a proper inspection every year with the boiler service by an OFTEC-registered technician.