Fire safety in HMOs: alarms, doors and risk assessments

HMOs need a written fire risk assessment of the shared parts and, usually, an interlinked fire alarm, fire doors on the escape route and sometimes emergency lighting.

Applies to: Every HMO. What you need depends on the size and layout of the house and your council's standards.

Checked against the official sources below. See what changed.

How oftenReview the fire risk assessment yearly; test alarms weekly or monthly; service panel systems on the BS 5839-6 schedule
Who can do itYou, or a competent fire risk assessor for larger houses; a fire alarm engineer for servicing
Typical costFire risk assessment about £200 to £500; alarm service about £80 to £200 a visit; fire doors about £300 to £800 each fitted
If it's missedFire Safety Order offences carry an unlimited fine and up to 2 years in prison; councils also enforce under the Housing Act

What the rules say

The common parts of an HMO (hallways, stairs, shared kitchens) come under the Regulatory Reform (Fire Safety) Order 2005, and you are the responsible person. That means a written fire risk assessment and the precautions it identifies.

Councils also judge fire safety under the Housing Health and Safety Rating System, and most follow the LACORS fire safety guidance for housing, which sets out alarm grades, fire doors and escape routes by house type. Licence conditions often spell out what is needed.

Free tools: Do I need an HMO licence? · Room size checker · Deposit deadlines · Licensing by council

What to do

  1. Do or commission a fire risk assessment of the common parts using the GOV.UK sleeping accommodation guide or LACORS. Write it down.
  2. Fit the alarm system it calls for: often a mains-wired interlinked Grade D system for a small shared house, or a Grade A panel system in larger or bedsit-style HMOs, with heat detection in kitchens.
  3. Check the escape route: 30-minute fire doors with self-closers on bedrooms and kitchens off the route, nothing stored in halls, and thumb-turn locks so nobody needs a key to get out.
  4. Add emergency lighting if the escape route has no natural light or the house is three storeys or more, and a fire blanket in each kitchen.
  5. Test the alarm regularly, log it, and have it serviced. Review the assessment yearly and after any change.

How landlords manage it in practice

  • Use the HMO safety log Record each alarm test, fire door check and emergency lighting test in the HMO records. A fault you log becomes a maintenance job straight away.
  • Make the first-day check routine Test every alarm with the new tenant on move-in day and record it. It is a legal duty and protects you if there is a dispute later.

Smoke and CO alarm rules apply too

The Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022 apply to all private rented homes in England: a smoke alarm on every storey with living accommodation, a carbon monoxide alarm in every room with a fixed combustion appliance (except a gas cooker), and repairs as soon as you are told one is faulty. Check they work on the first day of each new tenancy.

Alarm grades in plain English

Grade D alarms are mains-powered units with a battery backup, interlinked so one sets them all off. Grade A is a panel system with a control panel, installed and serviced by an engineer, usually needed in larger HMOs or where rooms are let as bedsits. Category LD2 or LD1 sets where detectors go: escape routes plus rooms that are a fire risk, or everywhere.

Elsewhere in the UK

Scotland: The Fire (Scotland) Act 2005 applies to the common parts, and HMO licences set the alarm and door standards in the Scottish Government's HMO guidance. All Scottish homes must also have interlinked smoke and heat alarms.

Wales: The same Fire Safety Order applies in Wales, and Welsh councils use the LACORS guidance. Contract holders' homes must also have working mains-powered interlinked smoke alarms on each storey under the Renting Homes (Wales) Act.

Northern Ireland: The Fire and Rescue Services (NI) Order 2006 and the HMO licence conditions set the standards. NIFRS and the council inspect.

Tips from the field

  • Bedrooms let with locks must open from the inside without a key.
  • Fire doors only work if they close. Check self-closers and intumescent strips at every inspection, and do not let tenants wedge them open.
  • Put a simple fire action notice by the front door and in each room: how the alarm sounds, the way out, where to meet and to call 999.

Common questions

Do I need fire doors in a small HMO?

Usually yes on rooms that open onto the escape route, especially kitchens and bedrooms. Your fire risk assessment and the council decide. Older solid doors can sometimes be upgraded rather than replaced.

Who has to test the fire alarm?

You or your manager. Many landlords ask a tenant to press the test button weekly and record it, with the landlord checking the log at inspections. Panel systems need servicing by a competent engineer.